<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-12 03-03-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 66 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 2.7 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 65 kHz 18956 0,0264
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,4 dBr 2,19 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Violin Concerto Op 35 I: Moderato nobile (Korngold Erich) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 65 kHz MIN: 9 kHz % above 76 kHz: 0,0264 Acquired: 2024/12/12 3.02.23 Total samples: 18956 Equivalent time: 0:15:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,7 dBr MIN: 1,4 dBr AVE: 2,19 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2024/12/12 3.02.22) 02.48 02.50 02.52 02.54 02.56 02.58 03.00 03.02 0 50 100 Dev. MAX [kHz] -1 0 1 2 3 4 Pm [dBr]